4.4.12 Fasten the power cable to the cable

guard

Figure 28 Outer guard and band in place - example

1. Inspect cable guards, particularly their inner

surfaces, for sharp edges that could damage
the cable jacket or insulation.

2. Support the cable alongside the pump bowl

assembly with the cable installation wheel
without stretching or straining the terminal
box.

CAUTION The attachment of the power cable

to the cable guard depends on the
type of the pump bowl assembly.

3.

Slightly lift the pumping unit.

4. Remove

the

U-plate.

Use to 2 persons to remove the
U-plate.

Handle the U-plate carefully.

Danger of injury by dropping the
U-plate onto parts of the body.

5.

Install a clamp to hold the pumping unit.

The pumping unit is now ready for the attachment
of riser pipe and lowering into the well.