Line integrity module specifications, Fuse replacement – GAI-Tronics 12389-001 NOVA PA/GA Systems S.M.A.R.T. Modules User Manual

Page 12

Advertising
background image

Pub. 42004-674L2H

NOVA

P

UBLIC

A

DDRESS

S

YSTEMS

-

S.M.A.R.T.

M

ODULES

P

AGE

10 of 24

f:\standard ioms - current release\42004 instr. manuals\42004-674l2h.doc
12/13

Line Integrity Module Specifications

Power input ....................................................................................... 24 V dc +/−20% @ 200 mA maximum
Physical size of each PCBA .............................................................................. 4 W

 15 L  4 D inches, and

3 W

 15 L  4 D inches

Operating environment ..................................................... 0

 C to 50 C @ 95 % humidity, non-condensing

Inputs ....................................................... Eight 100 V, 70 V, or 50 V audio line pass-through connections:

1200 watts maximum/channel

7.5 mm Euro-style wire-capture terminal strip accommodates wire sizes up to No. 10 AWG

System connection .................................... RS-485 I/O non-isolated, for external communication with CPU

Connection is via 8-pin modular jack

Two parallel connectors are provided

Two technical control switches for programming and line-fault determination

Outputs ...................................................................... Eight isolated alarm closures 220 V ac, off-withstand,

120 mA ac, 33 ohms, on

Connection method: ................................................................. 5 mm Euro-style wire capture terminal strips
Visual indication ..................................................... 11 LEDs for programming and line-fault determination
Line test output ................................................................................10 mA, or 20 mA, or 30 mA dc current;

or, 20 mA or 40 mA, or 60 mA dc current into 100 volt line

selected in firmware programming for line loop resistance test

Line test resistance range ........................................................................................................... 1 to 40 ohms

Fuse Replacement

CAUTION

For continued safe operation, replace fuses with the same type:

F1 is a Bussman GDC 500 mA fuse.

F2 and F3 are Bussman GDC 200 mA fuses.

N

OTE

: The Model 12604-014 Replacement Fuse Kit is available for all of the S.M.A.R.T. Modules. It

contains 10 of each of the required sizes.