Setting the individual tone output level, Test tone generator specifications, Fuse replacement – GAI-Tronics 12389-001 NOVA PA/GA Systems S.M.A.R.T. Modules User Manual

Page 14

Advertising
background image

Pub. 42004-674L2H

NOVA

P

UBLIC

A

DDRESS

S

YSTEMS

-

S.M.A.R.T.

M

ODULES

P

AGE

12 of 24

f:\standard ioms - current release\42004 instr. manuals\42004-674l2h.doc
12/13

Setting the Individual Tone Output Level

3. Connect only the field wiring for the channel which is having its output level adjusted. Disconnect

the other terminal blocks.

4. Set the Test Tone Generator into the Diagnostic mode by putting jumper P5 onto positions 2 and 3.

This will turn on the 35 Hz output continuously.

5. Adjust the pot for the channel being set so that the level of the 35 Hz tone at the farthest remote is

50 Vrms.

6. Repeat steps 3 and 5 for all channels in use, then put P5 onto positions 1 and 2 taking the Test Tone

Generator out of the Diagnostic mode.

Test Tone Generator Specifications

Power input ....................................................................................... 24 V dc +/−20% @ 150 mA maximum
Physical size .............................................................................................. 4.00 W

 6.50 L  1.250 D inches

Operating environment ................................................... 0

 C to 50 C @ 95 % humidity (non-condensing)

Inputs ..................................................... Four channels, low level (0 dBm) balanced audio line connections
Input impedance ............................................................................................ 600 ohms or 100 k

 selectable

Connection method ................................................................... 5-mm Euro-style wire-capture terminal strip
System connection .................................... RS-485 I/O non-isolated, for external communication with CPU

Connection is via 8-pin modular jack

Output ............................................................. Four channels, low level (0 dBm) balanced audio line driver
Output impedance ............................................................................................................................ 100 ohms
Connection method ................................................................... 5-mm Euro-style wire-capture terminal strip
Tone output level .................................................................................... Variable from +4 dBm to −46 dBm

Fuse Replacement

CAUTION

For continued safe operation, replace fuses with the same type:

F1 is a Bussman GDC 500 mA fuse.