CommandPLUS Series Desktop Console Installation and Service Manual

12/10 16

Ground Cable

The CommandPLUS Series Desktop Console is designed with a high degree of protection against electro-
static discharge (ESD), power line surges and telephone line surges. The protection circuitry is designed
to shunt the transient current to earth ground through the GND terminal, located on the back panel of the
console. This terminal must be connected to a high quality earth ground in order to obtain maximum
protection.

N

OTE

: This ground should be connected through a utility entrance ground cable and the telephone

entrance ground cable, if different from the utility ground. Lightning is essentially RF, and as such does
not like long leads or sharp bends. Make connections appropriately.

Channel Interface Cable

A 12-pair interface cable (one supplied for each four channels of operation) plugs into the 25-pin
D-connectors on the back of the console. Refer to Figure 2 showing the rear view of the console. The
ICP9004A 4-channel console employs only one 25-pin D-connector-cable assembly for connections to
the base station(s) control and audio pairs, generally through a termination block or connector. Refer to
Table 5 for wire colors and pin functions.

Table 5. Channel Interface Connectors and Cable Colors

Channel No.

Pin No.

Wire Colors

Pin Function

1 5 9

14
15
1, 2

White/Blue
Blue/White
White/Orange, Orange/White

TX Audio + /RX 2-Wire
TX Audio – /RX 2-Wire
RX Audio 4-Wire

2 6 10

3
4
5, 6

White/Green
Green/White
White/Brown, Brown/White

TX Audio + /RX 2-Wire
TX Audio – /RX 2-Wire
RX Audio 4-Wire

3 7 11

8
9
10, 11

White/Gray
Gray/White
Red/Blue, Blue/Red

TX Audio + /RX 2-Wire
TX Audio – /RX 2-Wire
RX Audio 4-Wire

4 8 12

12
13
24, 25

Red/Orange
Orange/Red
Red/Green, Green/Red

TX Audio + /RX 2-Wire
TX Audio – /RX 2-Wire
RX Audio 4-Wire


Some installations can use the optional CP0030A 25-pair Telco Interface Option, or the XCP0030A
25-pair Telco Interface Option Field Installation Kit, when the telephone company supplies a 50-pin
standard USOC, RJ21X Telephone Connector.

Power Supply (3308-00124-00)

The CommandPLUS Series Desktop Console uses an external power supply provided with the unit. This
is a self-contained unit that can be positioned on the desk with the console or located at some other
convenient spot. It requires an input of 90-264 V ac 50-60 Hz and delivers a regulated output of 12 V dc
at 4.2 A maximum.

Battery Revert Power Supply (XCP0080A)

The relay and associated devices for battery revert are incorporated on the main printed circuit board.
This option includes a modified power supply.