Model CB193-xxx, CB194-xxx, and CB195-xxx RF Call Boxes

Page

51 of 52

f:\radio products-current release\43004\43004-031e\43004-031e.doc
11/12

Telephone Number (telephone operation only): Allows for selection of the telephone number

that the Call Box will “dial” via the Telephone Interconnect unit. This code may contain up to
20 digits. The valid range for each digit is 0–9, A–D, *, #, or “,” (comma). The comma is used
as a pause.
N

OTE

: This applies only when Mode is set to “Telephone Interconnect.”

Busy Channel RF Lockout Retry Time: Sets the time that the Call Box will wait after

detecting airways activity for the channel to become clear. If the channel is busy at the end of
this interval, the Call Box will abandon the transmission, and revert to standby mode. If Mode is
set to “Radio,” then the valid range is 1 to 255 seconds in one-second increments. If Mode is set
to “Telephone Interconnect”, then the valid range is 20 to 255 seconds in one-second increments.
By default, retry time is set at 32 seconds.

Carrier Detect Check Enable: Enables or disables the monitoring of the channel prior to

transmission. Uncheck this box if the Call Box often indicates a busy channel due to low level
RF interference that does not hinder the use of this channel. By default, the carrier detect check
is enabled.

Carrier Detect Power Up Delay: Sets the time that the Call Box will wait after waking from its

battery-power-saving mode before it will monitor the RF channel for carrier. If the channel is
clear, then the ANI code or telephone number will be transmitted (if enabled), followed by the
transmission of voice audio. By default, the delay is set at 0 seconds.

Low Battery Warning Select (telephone operation only): Enables or disables the beep

transmitted to the telephone line when the battery level is low. N

OTE

: This applies only when

Mode is set to “Telephone Interconnect.”

8. Save entries by clicking on the

Apply

button.

9. Program the connected unit by right clicking on the Archive and highlighting the Program unit

command. The software will provide an indication that the unit was successfully programmed.

10. Disconnect power connection and XAC0004A Programming Cable.