Jumpers, Cmos cpu board (old style), Leds – Gasboy CFN Site Controller User Manual
Page 63: Switches, Leds switches
Advertising

Pump Interface Manual v1.3
Pump Control Unit
55
03/20/03
Gasboy CFN Series
Jumpers
CMOS CPU Board (old style)
Part number: C05321
LEDs
Switches
DIP switch banks B and C on the CMOS CPU board set options latched in at power-up time.
DIP Switch Bank B
Jumper
Setting
Setting
Default
K1
installed=battery
connected
removed=battery
disconnected
installed
LED
Color
Function
L1
red
422/485 transmit
L2
red
422/485 receive
L3, 4, 5, 6
red
submersible & slow flow, pump 1, 2, 3, 4
L7, 8, 9, 10
red
fast flow, pump 1, 2, 3, 4
Position & Definition
Setting(*=customary)
1-4
address
see below
5
address
*always closed
6
address
*always closed
7
baud rate
*open=9600
closed-see below
8
baud rate
*closed=9600
open-see below