Site controller iii pc (c07118) – Gasboy CFN Series Diagnostic Manual User Manual

Page 355

Advertising
background image

Site Controller III

1116

12-21

SITE CONTROLLER III PC (C07118)

The Site Controller III PC (which consists of a keyboard, mouse, monitor, case, and cables)
houses the site controller board set. The PC:

•

provides power to site controller board set

•

provides an interface to site controller board set

•

contains a hard disk drive for mass storage of PC operating system software, data and

application software

•

contains a 3-1/2" disk drive and a CD-ROM drive

•

contains a video and sound card

•

contains a minimum of 32M of RAM and minimum 200 watt power supply

•

contains PS/2 mouse port, 2 serial ports, and 1 parallel port

•

requires Windows NT OS version 4.0 or greater with Service Pack 3 or greater

•

requires Netscape V4.5 and AdobeReader V4.0 for the CFN on-line help

BIOS settings

The following BIOS settings are needed for the PC to work with the Site Controller III board set:

For Pentium 1 Computers

For Pentium 2 or 3 Computers

Under Advanced Setup:

•

PS/2 Mouse Support set to Enabled

•

Adapter ROM C800 – DC00, 16K set to

Disabled for all.

Under Advanced Setup:

•

Quick Boot set to disable

•

System BIOS Cacheable set to Enabled

•

CPU ECC set to Disabled

•

C000 – DC00, 16K Shadow set to Disabled

for all.

Under Chipset Setup:

•

Set IRQ 10 available to ISA/EISA. If using a

additional ISA expansion Comm port board
(for Integral Profit Pt PIN pad), set 5 & 9 to
ISA/EISA.

Under Chip Set Setup:

•

Memory Buffer Strength set to Auto.

Under Power Management:

•

Advanced Power Management is disabled.

Under PCI/PnP Setup:

•

Set IRQ 10 available to ISA/EISA. If using a

additional ISA expansion Comm port board
(for Integral Profit Pt PIN pad), set 5 & 9 to
ISA/EISA.

Under Peripheral Setup:

•

Programming mode is set to manual.

•

Set Serial Port 1 to 3F8H

•

Serial Port 2 to 2F8H

•

Parallel Port to 378H

•

Parallel Port Extended Mode to SPP

•

LPT IRQ Selection to IRQ 7.

Under Peripheral Setup:

•

Parallel Port Mode set to EPP

•

EPP version set to 1.9

•

Parallel Port IRQ set to 7.

Advertising