SITE COMMUNICATIONS I/O PCB (C06580)
The Islander II Site Communications I/O PCB:
•
interfaces with 2 of the site controller RS232 ports
•
provides the ability to select RS232 or RS422 communication
•
provides connection for internal modem
•
provides
diagnostic
LED’s
Layout
LED Indicators
LED
Function
Status
D1
Transmit data local port (or port 1)
Flashing when data transmitted to Islander
D2
Carrier Detect local port (or port 1)
Lit when carrier detect is received
D3
Receive data local port (or port 1)
Flashing when data received from Islander
D4
Data terminal ready local port (or port 1)
Lit when data terminal ready is on
D5
Carrier Detect remote port (or port 3)
Lit when carrier detect is received
D6
Transmit data remote port (or port 3)
Flashing when data transmitted to Islander
D7
Receive data remote port (or port 3)
Flashing when data received from Islander
D8
Data terminal ready remote port (or port 3)