Specifications:

All outputs are short circuit proof. Overloading of any output leads to shutdown of all
output supply voltages (except the MCA Batt output)
Ripple on all regulated outputs: <20mVpp on +5V, <6 mVpp on all other outputs. Ripple
measured with outputs loaded to 100 mA.
Operating temperature -5 ...+50°C
Size 155*95*50 mm, same as MCA166
Water and Dust protection IP42
6W total power output maximum
Contains 3 camcorder type Li-Ion batteries, 4 Ah/ 30Wh
Standby current (power supply switched on, no load): 35mA
Overload recognition: If all output voltages are correctly present, the indicator LED is
blinking with a frequency of about 0.5 Hz. If there is a voltage drop of more than 10%,
then the LED starts blinking fast (3 Hz); and if this persists for more than 1.5 seconds, the
power supply is switched off. To reset the power supply, switch it off, wait a second and
then switch it on again.

Charge input connector

Contact

Signal

1

+ charge voltage (8.4V,1A max)

2

- charge voltage

MCA Batt output connector

6.6..8.2V, depending on Battery charge state, 1A max.
Wiring of Output connector same as input connector

Power Supply Connectors (D9 female) + BNC

Contact

Voltage

warranted
Current

for

output voltage
within +/- 5%

max. Current
before
switching of.

D9-1

GND

D9-2

GND

D9-3

+5 +/-0.25V

300 mA

550 mA

D9-4

+12 +/- 0.6 V

130 mA

570 mA

D9-5

-

D9-6

-24 +/- 1.2 V

100mA

150 mA

D9-7

+24 +/- 1.2 V

100 mA

160 mA

D9-8

-

D9-9

-12 +/- 0.6 V

130 mA

260 mA

BNC

Connected to
D9-3

all current under condition that the total power output limit is not exceeded.