Wash firing (foundation)

The restoration must be free of dirt and grease prior to the application of the wash. Any

contamination after cleaning must be prevented. Wash firing is carried out with IPS e.max

Ceram Deep Dentin or IPS e.max Ceram Dentin.

The following steps must be observed:

– Use the IPS e.max Ceram Build-Up Liquids allround or soft to mix

the Deep Dentin or Dentin materials. If a more plastic consistency is

desired, IPS e.max Ceram Glaze and Stain Liquid allround of longlife

can be used.

– Apply the wash in a thin coat on the entire restoration.

Optional

Wash firing (foundation) characterization

IPS e.max Ceram Essence can be used to design intensively characterized areas. These materials are

excellently suitable for individualized characterizations.

Layering materials must not be applied on unfired wash layers, since this will result in a delamination of the

layering ceramic. The wash (foundation) must be fired before the actual layering procedure is started.

Firing parameters for the Wash firing (foundation firing) characterization

Firing parameters for the Wash firing (foundation firing)

Conduct the wash firing with Deep Dentin or Dentin materials.

IPS e.max Ceram on IPS e.max ZirPress

B

S

t

T

H

V

1

V

2

L

Cut-Back and Layering Technique

°C/°F

min.

°C/°F/min

°C/°F

min.

°C/°F

°C/°F

°C/°F

Wash firing (foundation)

403/757

4:00

40/72

750/1382

1:00

450/842

749/1380

0

IPS e.max Ceram on IPS e.max ZirPress

B

S

t

T

H

V

1

V

2

L

Cut-Back and Layering Technique

°C/°F

min.

°C/°F/min

°C/°F

min.

°C/°F

°C/°F

°C/°F

Wash firing (foundation) characterization

403/757

4:00

40/72

750/1382

1:00

450/842

749/1380

0