Preparing the Straumann

®

Anatomic IPS e.max

®

Abutment

The Straumann Anatomic IPS e.max Abutment is prepared according to the step-by-step instructions.

For the selection of the grinding instruments, please refer to the Ivoclar Vivadent Flow Chart

”Recommended grinding tools for IPS e.max zirconium oxide”.

Conduct a Regeneration firing (see page 15) after preparing the abutment

Individualized Straumann

®

Anatomic IPS e.max

®

Abutment on the model

Firing parameters for the Regeneration firing

Furnace

P300
P500
P700

EP 3000
EP 5000

P80

P100
P200

EP 600

PX1

B

°C/°F

403
757

403
757

403
757

S

min

0:18

0:18

0:30

t

1

°C/°F/min

65

117

65

117

65

117

T

1

°C/°F

1050
1922

1050
1922

1050
1922

H

1

min

15:00

15:00

15:00

L

°C/°F

750

1382

750

1382

750

1382

12 min

t

°C/°F/min

25
45

––

––

Please observe the following procedure for conducting the Regeneration firing:

– Clean and dry the abutment with a steam jet.

– Position the abutment on a metal pin on a honey-combed tray.

– Conduct the Regeneration firing in a ceramic furnace (e.g. Programat P700) using the respective parameters.

– Do not adjust the abutment by grinding after the Regeneration firing.

– Do not blast the framework with Al

2

O

3

or glass polishing beads before veneering, since this may cause lasting damage

to the surface.

– Before veneering, clean the abutment with running water or the steam jet.