Firing parameters for IPS Eris for E2 dentin, incisal, and
Impulse material firing (220 V)

Occlusal view of the completed layering.

The same procedure is used for single restorations. Here, a premolar is shown.

…and completed with the incisal layering.

P

B

403 °C

757 °F

t

60 °C

108 °F

T

755 °C

1391 °F

S

6
6

H

2
2

V

1

450 °C

842 °F

V

2

754 °C

1389 °F

L


Any additional firing cycles can be carried out
using the same firing program.

When finishing bridges, only the interproximal area of the
layering material should be separated.

Do not use separating disks to work on the high-strength
frameworks.

Important

When working with a furnace from another

manufacturer, these parameters have to be
adjusted accordingly.

P

B

403 °C

757 °F

t

55 °C

99 °F

T

765 °C

1409 °F

S

6
6

H

2
2

V

1

450 °C

842 °F

V

2

764 °C

1407°F

L


Firing parameters for IPS Eris for E2 dentin, incisal, and
Impulse material firing (110 V)