The tooth shape and function are designed with the help of a wax-up and secured with a silicone key.

Minimum material thicknesses / layer thicknesses

The restoration design is key to the success of a temporary restoration. The more attention given to the
design, the better the final results and the clinical success will turn out to be.

The following basic guidelines have to be observed:
– Support the restoration with a framework (metal, Vectris) in long-span bridges or if space is limited.
– The minimum wall thickness of 1.5 mm occlusal and 0.8 mm circular must be observed at all times.
– The connector dimensions for anterior bridges with up to two pontics must be at least 12 mm

2

– The connector dimensions for posterior bridges with one pontic must be at least 12 mm

2

and with up

to two pontics at least 16 mm

2

Wax-up