Uses telio lab, Telio cad – Ivoclar Vivadent Telio Lab User Manual

Page 6

Advertising
background image

Uses

Telio Lab

Indications

Temporary metal-free crowns and bridges with
a maximum wear period of 12 months

Temporary metal- or Vectris-supported crowns
and bridges with a maximum wear period of
12 months

Characterization, repair, supplements and
relining of temporaries

Cementation of Ivoclar Vivadent denture teeth
to removable dentures (e.g. model cast
dentures)

Esthetic modification of denture teeth

Contraindications

Direct intraoral use of unpolymerized material

The material should not be used if a patient is

known to be allergic to any of the ingredients
of Telio Lab

Patients with parafunctions, e.g. bruxism

Long-span bridges without reinforcements for a
wear period longer than 12 months

Occlusal appliances to elevate the vertical
dimensions

Telio CAD

Indications

Temporary anterior and posterior crowns with a
maximum wear period of 12 months

Temporary anterior and posterior bridges with
up to 2 pontics with a maximum wear period
of 12 months

Implant temporaries

Shape templates for permanent restorations

Therapeutic restorations to correct TMJ
problems and occlusal adjustments

Contraindications

Use for permanent restorations

Bridge reconstructions with more than two
pontics

Use of an incompatible / non-authorized
CAD/CAM system

Patients with parafunctions, e.g. bruxism

The material should not be used if a patient is
known to be allergic to any of the ingredients
of Telio CAD

Important processing restrictions
Failure to observe the following restrictions may
compromise the results achieved with Telio Lab
and/or Telio CAD:

Failure to observe the general Telio Lab
minimum layer thickness of 1.5 mm

No evenly supporting framework design

Long-span bridges without reinforcement

Insufficient connector dimensions

Lack of mechanical retentions on the veneering
surface of the metal framework, (e.g. SR Micro,
SR Macro Retention Beads from Ivoclar
Vivadent)

Staining/layering using materials that are not
approved and/or recommended

Milling the Telio CAD blocks in an no-
compatible CAD/CAM system

For the processing of Telio CAD with the inLab

®

MC-L and/or CEREC

®

MC-L System from Sirona,

the CAD-Waxx Starter Kit (Sirona) with modi-
fied tank and reinforced filter system is required
(available from dental dealers). In comparison
with ceramic materials, a reduced quantity of
Dentatec fluid per tank filling is required
(milling additive) (see Ivoclar Vivadent abrasives
overview).

6

Prevention of premature loss of retention:
Apart from a retentive preparation design, the
reliable cementation of Telio CAD restorations
using a temporary luting material (e.g. Telio CS
Link) depends on the accuracy of fit, which is
determined by the CAD/CAM system used.

Advertising