Setup – Leprecon LP-612 User Manual

Page 5

Advertising
background image

4

Setup

The LP600 connects easily to most types of dimming systems. Microplex, as well as the optional
analog and DMX 512 outputs are provided for dimmer control. The flexibility to interface to various
systems makes the LP600 a natural choice for building a new system, or upgrading an existing
system.

Power requirements

The LP600 console can be powered in two ways.

a) With Microplex dimmers, the microphone cable between the dimmer and controller supplies
board power. No external supply connection is required.

b) With DMX and analog options, an external supply must be used to power the board. This
transformer is supplied as part of the option package. This transformer is rated for 12VAC at 800
milliamps.

If the board is to be used with European power systems, or other 230 volt applications, contact
your Leprecon dealer for the correct 230 volt power supply.

Microplex Output

The three pin XLR connectors at the back of the LP600 are used to connect the board to standard
Microplex dimmers. This connection will work with Leprecon 360 Microplex dimmers, and has
been tested with other products for compatibility.

Microplex is suitable for use in smaller systems, up to 64 channels. Ordinary microphone cable
may be used to connect the LP600 to Microplex dimmers.

DMX Output

The DMX 512 digital output on the rear panel offers a fast and reliable way of sending control
information to the stage. Simply connect a 5-wire DMX control cable from the console output to
the DMX input on the dimmer. As the standard mandates, the LP600 has a 5 pin XLR female
connector. Additional dimmers can be "daisy-chained" from the first dimmer, by running additional
cables between the dimmers.

DMX512 uses a high speed digital signal, and the correct cable type is essential for reliable
operation. Microphone cable is not DMX cable. Use of microphone cable for DMX 512 is not
recommended.

The LP600 has been tested and complies fully with the USITT DMX 512/1990 standard, and
should pose no compatibility problems with any DMX 512 dimmers from Leprecon or from other
manufacturers. Should any suspected incompatibilities be encountered, please contact your
Leprecon dealer with the specific dimmer model and manufacturer.

Advertising