Leprecon LP-612 User Manual

Page 6

Advertising
background image

5

Analog Output

Even with the advent of digital control standards, many portable lighting systems use analog
control lines between the console and the dimmer racks. The LP600 provides 0-10 volt analog
outputs, using Cinch-Jones connectors. The pin connection of these connectors is identical to that
used on many other Leprecon products.

Connector Pin Assignments : LP612 ONLY

The analog version of the LP612 uses two panel mount male Cinch-Jones 8 pin connectors for
control output. The pin connections are as follows:

1

2

1

8

1

8

Connector 1

Pin

Function

1

Channel 1

2

Channel 2

3

Channel 3

4

Channel 4

5

Channel 5

6

Channel 6

7

No connect

8

Common

Connector 2

Pin

Function

1

Channel 7

2

Channel 8

3

Channel 9

4

Channel 10

5

Channel 11

6

Channel 12

7

No connect

8

Common