7 menu system – LSC Lighting EKO User Manual

Page 22

Advertising
background image

EKO Dimmer

Operator Manual V2.3

Page 18

LSC Lighting Systems (Aust) Pty. Ltd

7 MENU

SYSTEM

7.1 TOUCH SCREEN MENUS

When the EKO is switched ON, after briefly
showing the opening screen, the top level
screen appears;


Pressing [Menu] reveals the “Main Menu”.

The six buttons on the “Main Menu” provide
access to the Sub-Menus and functions which
are described in detail on the following pages.
Each sub menu has a description of its function
at the top of its screen.

7.1.1 EKO Menu Structure

Each main menu button accesses the following sub menu functions;

Dimmer

Channels

Set-up

Chan Test

Control Source.

(DMX, Memory or

Switch)

Min Level

Max Level

Fade Curve

Net Group Master.

Manual channel(s) level test

Channel test sequencer



DMX

Input

Patch View

Levels

1:1 Patch

User Patch

Clear Patch

Raw levels

Percentage

Connect Loss Action

DMX Alarm

DMX Control
Hold Time
Xfade Time
Backup Memory

Via DMX/MEM Switch
Auto Switch On/Off
Hold Time
Xfade Time

Alarm Enable/Disable

Alarm Delay Time

Memories

Record
Memory

Edit
Memory

Copy
Memory

Delete
Memory


Net

Setup

MEM/DMX
Switch

Manually operate the
“MEM/DMX Switch”.

Switch Group

Set Switch Group
Number or None for
ePlate control of
MEM/DMX Switch.

Options

Module Status

Beeper About

Input Phases
A B C

Temperature

Fan Speed

On
or
Off

Software
Version

Model type

Voltage

Lock Dimmer
4 digit code to
lock

Change Lock
Code
Default = 0000

Dimmer Name
Enter a name

Date and
Time

Set Time

Set Date

Net Playback

Enable or Disable
Memory playback
from ePlates

Reset

System Reset

Total Reset

Log

Displays Log

Clear Log

Advertising