Menus

EKO Dimmer

Operator Manual V2.3

Page 28

LSC Lighting Systems (Aust) Pty. Ltd

You can copy more memories or if finished
press [Exit], [Done] [Done].

7.4.5 Delete Memory

To delete a memory press:
Press: [Menu], [Memories] [Delete Memory].
The current output of the EKO dimmer (if any) is
blacked out.
Select a memory to be deleted. As each
memory is selected its contents are shown on
the output of the EKO and also on the channel
indicators. This allows you to preview the
contents of each memory on the output and
make the correct choice.
When the correct memory to be deleted is
selected, press [Pick]. To confirm, press [Yes].
You can delete more memories or if finished
press [Exit], [Done] [Done].

7.5 NET SETUP MENU

The “Net Setup” menu is used to control the
manual operation of the DMX/MEM Switch.
Press; [Menu], [Net Setup].

Note: If [Net Setup] is greyed out (not
available), then playback via LSCnet has
been disabled from the options menu. This
option can be selected when the EKO is only
to be controlled by DMX. See “Options
menu” for details.

7.5.1 DMX/MEM Switch Operation

All channels that have their “Control Source”
attribute set to “Switch”, can be switched
between either “DMX” control or “Memory”
(ePlate) control.
The DMX/MEM Switch can be operated from a
suitably programmed button on an ePlate or
directly from the LCD touch screen on the EKO.
To manually operate the “DMX/MEM Switch”
from the touch screen, press;
[Menu], [Net Setup] [DMX/MEM Switch].


Select either; [DMX] or [Memory] then press
[Set].

7.5.2 Switch Group

An ePlate button that has been programmed to
operate the DMX/MEM Switch can also be
programmed with a “Switch Group Number”.

You can set the DMX/MEM Switch in each EKO
to only be operated by a particular “Switch
Group Number”.
Therefore, in setups with more that one EKO,
individual ePlate buttons can be programmed to
only operate the DMX/MEM Switch in EKO
dimmers with the matching “Switch Group
Number”.
To set the “Switch Group Number”, from the
“Net Setup” menu (above) press;
[Switch Group Number].


Enter the required Switch Group Number in the
range from 001 to 255 (to match the required
ePlate button) or for no Switch Group press
[Disabled], then press [Set] [Done] [Done].

7.6 OPTIONS MENU

Selecting [Menu] [Options] provides menus for;

• Module

Status

• Beeper

• About

• Lock

Dimmer

• Change Lock Code

• Dimmer

Name

• Date and Time

• Net Playback: Enable/Disable

• Reset

7.6.1 Module Status

Depending upon the model of your EKO it may
contain one or two internal modules.
Pressing [Menu] [Options] [Module Status]
reveals information about the input power
phases, temperature and fan speed of the
internal dimmer module(s) of the EKO.

.

EKO model with 2 Modules.