Teach-in-methoden, Analog output setting, Switch output setting – Microsonic LCA-2 User Manual

Page 40

Advertising
background image

Page 40 of 51

Parameter change in the web edge sensor bks+

T

EACH

-

IN

-M

ETHODEN

To adjust the zero position of the edge to be controlled, the sensor can be calibrated with two options.

Completely freeing the fork from the web material

push

, then completely fill sensor fork and

push

.

Or align the web edge inside the fork with the two marks to ensure a 50 % coverage of the sound path,

then push

.

Ready.

A

NALOG OUTPUT SETTING

The analog output can be adjusted so that it supplies current or voltage. The characteristic can be
selected as rising or falling.

Voltage / Current Increasing:

voltage / current increases with higher coverage

Voltage / Current falling:

voltage / current drops with higher coverage

S

W ITCH

O

UTPUT

S

ETTING

The switched output of the bks+../FIU or bks+../F can be used e.g. for monitoring purposes. He switches
around the (adjustable) center in a (adjustable) window.