Filter setting, Other setting – Microsonic LCA-2 User Manual

Page 41

Advertising
background image

Parameter change in the web edge sensor bks+

Page 41 of 51

F

ILTER

S

ETTING

The filter type F can be chosen from 0 to 3. Where is:

0: No Filter

1: Moving average

2: Median filter

The filter strength can be varied for each filter types between 0-9.

O

THER

S

ETTING

LED

S OFF

30

SECONDS FROM LAST KEY PRESS

:

If this feature is activated, the LEDs are off 30 seconds after the last key press. This is needed eg for light-
sensitive materials.

CHARACTERISTICS LINEARIZATION

:

The characteristic is linearized so that it has a straight course within its limits.

T

EMPERATURE COMPENSATION

:

see Temperature compensation on page 19

T

OUCH

C

ONTROL

:

see Fehler! Verweisquelle konnte nicht gefunden werden. on page 19