4-3 Set sensor

The system supports up to four sensor inputs.

☞ OPTION : Able to use up to 16 alarms and sensors when using separate “extended alarm
sensor box”.

How to set menu : retrieve menu -> EVENT -> SENSOR



▶ Select Use Y/N.

(Use) (Not use)


▶ Input method : Choose between Normal Open and Normal Close.

N/Open (NORMAL OPEN) : Generate signal when contact point closes after it was normally

left open

N/Close (NORMAL CLOSE) : Generate signal when contact point opens after it was normally

left closed


▶ Linked channels: Able to use by linking a sensor to multiple channels.

(Not use) (Use)