Powered Tests

36

Err 03 with flashing cross

Internal relay fault

Return to your Service Agent if problem persists.

Err 04 with flashing cross

Internal relay fault

Return to your Service Agent if problem persists.

Err 05 with flashing cross

Internal relay fault

Return to your Service Agent if problem persists.

Err 06 with flashing cross

Internal relay fault

Return to your Service Agent if problem persists.

Err 07 with flashing cross

Memory corruption.

Return to your Service Agent.

Powered Tests

The Tester performs a number of checks prior to and during powered
tests. The following primary display messages can occur.

Lo Po

Low power caused by load less than 60w. The user can override this
message if low load is expected by pressing the START/STOP
button.

Hi Cu

High current is expected to be drawn by the EUT. This message
appears if the current is greater than 16A. The user can override this
message, provided the current is not expected to exceed 50A, if it is
caused by a high start up current by pressing the START/STOP
button.