AC Earth Continuity Test

42

Chapter 6 Specifications

AC Earth Continuity Test

Test Voltage *.. ............................................6V rms nominal (no load)

Test Current *......................................................... 10A (into s/c load)

Range............................................................................. 0m

Ω - 19.99Ω

Resolution. ................................................................................. .0.01

Accuracy..................+/- 5% of reading, +/- 2 digits (0.05 - 5.00 ohms)

Pass Levels. ........................................................... 0.1

Ω, User defined

Misc.............................................. ..4-wire measurement, floating earth

DC Earth Continuity Test

Test Voltage *. ...............................................4V dc nominal (no load)

Test Current * .....................................+200mA, -200mA (into s/c load)

Range ......................................................................... .00m

Ω - 19.99Ω

Resolution. ................................................................................ ..0.01

Accuracy..................+/- 5% of reading, +/- 2 digits (0.05 - 5.00 ohms)

Pass Levels. ............................................................0.1

Ω, User defined

Misc............................................... .4-wire measurement, floating earth

Insulation Test

Test Voltage * .............. 500V d.c. or 250V d.c. nominal (0.5M

Ω load)

Short Circuit Current ............................................ 2mA d.c. maximum

Range............................................................................ 00k

Ω - 100 MΩ

Resolution .............................................................0.01 M

Ω (<100 MΩ)

Accuracy...................... .+/- 5% of reading, +/- 2 digits (100k

Ω - 5MΩ)

Pass Levels….. ..….0.25M

Ω, 0.50MΩ, 1.0MΩ, 2.0MΩ, User defined