SVSi N2000 Series User Manual

Page 45

Advertising
background image

Page 45

N2000 Series User Manual

www.svsiav.com

Chapter 3. Encoder Options

Advanced Settings

IR Command
Holdoff

Set the delay between IR command
portions. The default setting is 25 ms.

IR commands are sent in two parts.
This setting is the time (in
milliseconds) between transmission of
part one and part two. The second part
of the command is inverted for
confirmation purposes.

IR Repeat Holdoff

Set the repeat delay between IR
commands. The default setting is 90
ms.

This is the amount of time before a
new command is sent. For example,
when pressing and holding the volume
button on a remote control, this is how
long until the command is repeated.

Maintain Aspect
Ratio

When scalers are enabled, enabling
this check box maintains the source’s
aspect ratio.

Enable SNMP

Enable to allow the device to handle
Simple Network Management Protocol
(SNMP) queries.

Table 3-2. Settings Page: Advanced Settings (Continued)

Option

Description

Notes