Edid section – SVSi N2000 Series User Manual

Page 53

Advertising
background image

Page 53

N2000 Series User Manual

www.svsiav.com

Chapter 3. Encoder Options

EDID Section

EDID Section

The EDID (Extended Display ID Data) section of the Settings page is shown in

Figure 3-10

. Options are

described in

Table 3-7

.

Edit the Encoder’s EDID if you need to change the device type it appears as to the source. There are two
different ways to control the EDID of the Encoders.
Option 1: Use the default settings drop-down menu and select from the options available. Then click Reset
EDID
. This will work for most sources and is most often set to Stereo (2 channel).
Option 2: When using an EDID captured from a source connected to an Encoder, paste the data in to the
white EDID block, overwriting existing EDID. Then click Set EDID.

Figure 3-10. EDID Section

The source will need to be disconnected while modifying EDID settings.

Table 3-7. Settings Page: EDID Section

Option

Description

Show EDID

Click this link to view the Encoder’s current EDID table.

Read local EDID

Click if source EDID has changed (refreshes the EDID table).

Set EDID

If pasting a custom EDID, click to apply the changes.