Data communication settings

By connecting a PC through its RS-232C terminal to

the MD-CD1MKIII through its CONTROL I/O (RS-232C)

terminal, the two units can be linked for data exchange.

Use the following options on the SERIAL sub-menu of the

CD menu to perform their respective settings.
BAUD RATE
Sets the communication speed of the keyboard.
4800/9600/19200/38400 bps can be selected.
Default: 9,600
LENGTH
Communication word length can be set to either 7 or 8

bits.
Default: 8 bits
PARITY
Communication parity can be set to NON, EVEN or ODD.
Default: NON
STOP BIT
The data stop bit can be set to either 1 or 2.
Default: 1

Viewing service data

You can view service data via the following items in the

SYSTEM submenu of the CD menu.
CD P_TIME
The total CD playback time is shown.
MD P_TIME
The total MD playback time is shown.
MD R_TIME
The total MD recording time is shown.

Initializing all data

You can reset all data to initial default settings.
1 Make sure that no disc is loaded in the MD or

CD player. Select the

F_PRESET

? option on the

SYSTEM sub-menu of the CD menu.
The display indicates

Sure?

.

2 Press the MULTI JOG dial (or YES button) on the

unit or the ENT/YES button on the remote control.
All data will be initialized to the default settings.

CAUTION

Do not turn off the power to the unit until the

•

Complete

indicator on the display disappears.

If the settings are initialized, all the programs retained

•

for each disc will be erased.

14 – Data settings/Service Data