Configuring the T1 Network

5-22

Access Manager 2000 User Manual

ComDesign: The node’s network management port connects to a
statistical multiplexer.

X.25 PAD: The node’s network management port connects to an
X.25 PAD (Packet Assembler Disassembler).

Table 5-5

Node configuration options for older equipment

This includes the for 551VST List 1, 551VST List 1/A, 551VST List 1/B, and 551VST ML List 1. These equipment types
use TABS Protocol and do not support alarm reporting.

Table 5-6

Node Configuration Option for newer equipment

This includes the 551VST (ML) List 2, SIM, NC/E, ConnecT1 Plus, and AS2000. These equipment types use OSI
protocol. The X.25 PAD can only be used with AS2000 equipment.

Access Arrangement (Connection)
Option

Direct

Modem

None
(Facility Data Link
or Daisy Chain)

ComDesign

Baud Rate (Note 1)

1200

1200

1200

120

Query Path

COM 1-16

Phone No.

None

Port Name

Enable Alarm Reporting

No

No

No

No

NOTE 1. Currently, a modem (Comline) configured for 2400 baud cannot initiate calls to a node configured for
1200 baud. Configure the node in Access Manage for 2400 baud, and allow the modem to automatically
downgrade to 1200 baud.

Access Arrangement
(Connection) Option

Direct

Modem

None
(Facility Data Link
or Daisy Chain)

ComDesign
or
X.25 PAD

Report alarms:

Baud Rate (Note 1)

9600

1200/2400

1200/9600

9600

Query Path

COM 1-16

Phone No.

None

Port Name

Alarm Path

COM 1-16

Phone No.

None

Access Manager Port
Name

Previous Node in Chain
(Note 2, 3

Node Name

None

None

None

Enable Alarm Reporting

Yes

Yes

No

Yes

Do not report alarms:

Alarm Path

None

None

None

None