Verilink Access Manager 2000 (896-502037-001) Product Manual User Manual
Page 386

E-4
Access Manager 2000 User Manual
■
Table E-11, “NMC List 2 Alarm Bit Definition 2,” on page E -10.
This table lists the NMC List 2 alarm bits for the 4016 L1 or L2
when the plug-in number is zero.
Note:
If the Node type (Field #11) of the reporting node is Access
System2000 and the far-end circuit element is 551VST type, then
the only far-end alarm Status Codes (Fields # 13-27) reported
are: 301, 302, 311, 312, 313, 314, 409, and 410..
Table E-2 Alarm Archive Record Layout for ESF CSU
Field No.
Description
1
Year, last two digits
2
Month
3
Day
4
Hour
5
Minutes
6
Seconds
7
Circuit element name (i.e., node name [shelf, slot])
8
Node ID number
9
Shelf number, less than or equal to 128 if the alarms reported are set conditions. Otherwise, the
alarms reported are clear conditions.
10
Plug-in number 9 (i.e., slot number)
11
Node (or Circuit Element) type:
26 = 551VST List 2
33 = NC/E
32 = SIM
24 = NMC List 2