Verilink Access Manager 2000 (896-502037-001) Product Manual User Manual

Page 362

Advertising
background image

C-4

Access Manager 2000 User Manual

Table C-2 551VST List 2 Status Code

Table C-3 NC/E Status Codes

15

n + 2

1

Byte n+2 is a One-byte checksum. This checksum is 2’s complement
of the sum of all bytes in the alarm record (modulo 256), excluding
the SOH (Field 1) and terminator (Field 14) bytes.

Status Code (hex)

Description

00

Near BER exceeded

01

Near SPAN LOS alarm

02

Near EQPT low density

03

Near LLB or PLB looped

04

Near ELB or RLB looped

08

Far BER exceeded

09

Far SPAN LOS alarm

0A

Far EQPT low density alar

0B

Far LLB or PLB looped

0C

Far ELB or RLB loope

0F

Far CSU absent alarm

Status Code (hex)

Description

00

Near BER exceeded

01

Near SPAN LOS alarm

02

Near EQPT low density alarm

03

Near LLB or PLB looped

04

Near ELB or RLB looped

06

Near fuse blown

07

Near CSU absent alarm

08

Far BER exceeded

09

Far SPAN LOS alarm

0A

Far EQPT low density alar

0B

Far LLB or PLB looped

0C

Far ELB or RLB loope

0F

Far CSU absent alarm

Field

Byte

Length

Description