Resetting user performance registers – Verilink Access Manager 2000 (896-502037-001) Product Manual User Manual
Page 308

Monitoring and Troubleshooting Access Manager
8-38
Access Manager 2000 User Manual
Resetting User performance registers
Use this sub-menu to reset User registers. The NCC, CCC, and TAC do
not maintain CV-L and CV-P performance data registers.
To reset user performance registers:
1. When you get the On-line Access sub-menu, select
Reset USER
Registers
. The Select Registers to Reset screen appears.
2. Enter
Y
for all those registers you wish to reset. Enter
N
for those
that should not be reset.
■
Near end Performance Data Registers:
Include User, Additional (AS2000 only), and EQPT (AS2000 only)
registers.
For AS2000, these are NET side: ES, UAS, BES, SES, LOFC, ES-
L, SEFS, and OOFS.
Included for AS2000 CSUs are NET side: LOFS, LOSS, RAIS,
AISS, and BERS; and the EQPT side: ES, UAS, ES-L, OOFS,
DTED, and DBER registers.
■
Near end ESF Error Events Register:
The sum of the following error events: CRC-6 errors and OOF
events. (See AT&T54016).
■
Far end CV-L Events Register: