Verilink Access Manager 2000 (896-502037-001) Product Manual User Manual

Page 96

Advertising
background image

Configuring Access Manager

4-10

Access Manager 2000 User Manual

Digiboard COM port. Refer to the DOS manual for proper use of the
MODE command. Do not duplicate filenames listed in Table 2-1,
“Access Manager Installation Files,” on page 2-4.

To output alarm messages to another computer:

1. In the

Alarm Printer Filename

field, enter the comline

name.

2. Leave the

Printer Type

field blank. It is not applicable.

Alarm Channel Protocol

The

Alarm Channel Protocol

data entry field appears in the

Editing the Alarm Destination screen. The

Alarm Channel

Protocol

option is selected by moving the cursor to that line and

pressing

to bring up the selection

Alarm Channel

Protocol

screen.

If you are using a serial or parallel printe , select the

PLAIN ENGLISH

MESSAGE

option. This sends the entire alarm information in ASCII

format. The alarms are printed one alarm message per line.

If you are outputting to a serial port or disk file, select the

TERSE

MESSAGE

option. This sends information in the following formats:

the date, time, and node name alarm output in an ASCII format, and

the alarm status in an ASCII-formatted hexadecimal format.

Do not use this option with a serial or parallel printer.

F8