Port usage, Port usage -5 – Verilink NCC 2020 (880-503284-001) Product Manual User Manual

Page 13

Advertising
background image

Overview

Verilink NCC 2020 User Manual

1-5

Port Usage

Table 1-3

lists the connectors on both front and rear modules with

details about their uses:

Table 1-3

NCC 2020 Connector Ports

Port

Located

Usage

Craft

Front

Connect ASCII terminal for configuration, diagnostics, alarm monitoring,

and/or performance monitoring.

Bantam Jacks

Front

Monitor network signals, DSX-1 equipment signals, connect T1 test

equipment.

These ports do not reflect line signals unless the module

is in CSU mode

. Use only when in CSU mode (DIU bus = none).

Network

Rear

Connect the T1 line to this port.

Eqpt

Rear

Connect customer equipment which presents a DSX-1 T1 framed signal —

often a PBX. This port is only used if the module is in CSU mode or Drop and

Insert mode.

Management

Port In

Rear

Connect a cable directly or a modem for dialup connection to a PC running

either of the Verilink management programs — AM2000 or Node Manager.

Management

Extension

Rear

Connect a cable to an additional node at the same location. This feature is

only supported when AM2000 is used for node management.

Ext Timing

Rear

Connect an optional external clock source, using either a TTL (Transistor

Transistor Logic) level (0 to +5V) or balanced (RS-422) signal. The clock must

be at 1.544 Mbit/s.

Alarm Relay

Rear

Connect an external alarm system which will trigger on either a relay closure

(using NO and COM leads) or an open (using NC and COM leads). The relay in

the NCC module supports Form C relay specifications.