Verilink NCC 2020 (880-503284-001) Product Manual User Manual

Page 61

Advertising
background image

Diagnostics

Verilink NCC 2020 User Manual

5-13

With a loopback plug in the network port, any customer equipment
connected to the NCC 2020 (or a data port of any DIU module
assigned to the CSU) should see a loopback condition. If the
customer equipment can report errors, it should indicate that no
errors are being received.

A T1 loopback plug can be made by taking a male RJ-45 connector
and placing two short jumper wires where a cable would normally
go. One jumper is placed from pin one to pin five, the other jumper
connects pin two to pin four. See

Figure 5-5

for

a drawing of a T1

loopback plug.

NOTE: When using a T1 loopback plug it may be necessary to

temporarily change the timing selection in the CSU. If the

CSU is set to recover network clock, it will be trying to recover

a clock it is trying to recover, the clock frequency will drift.

For this test, set the CSU clock source to Internal. Remember

to change it back after the test.

Figure 5-5

T1 Loopback Plug

RJ -45

8

Cable Side

Connector

2

4

5

1

RJ-45 plug held with plastic latching tab unseen at bottom

Advertising