The options on the Management Channel Menu are documented in

Table 3-6

below.

Table 3-6

Management Channel Menu Commands

Menu Option

Description

Instructions

Type T)

Configure Management

Channel - TYPE returns

this list of choices:

type (1) direct (2) modem

type (1) direct (2) modem

type (1) direct (2) modem

type (1) direct (2) modem

(3) stat mux (4) auto (5)

(3) stat mux (4) auto (5)

(3) stat mux (4) auto (5)

(3) stat mux (4) auto (5)

none (6) x.25 pad >

none (6) x.25 pad >

none (6) x.25 pad >

none (6) x.25 pad >
Selections 3 and 6 may be

used only with Access

Manager 2000 as the

network management

program.

Node Manager supports

direct or modem

connections to an NCC

module.

(1) direct —Select only if the NCC is co-located with

the PC running AM2000 or Node Manager and it is

directly connected via an RS-232 cable.

(2) modem —Select if the NCC has a modem

connected. Use a Verilink part number 458-501771-

008 cable to make the connection from the

MANAGEMENT PORT IN

on the rear interface connector

module to the DB-25 connector on your modem.

(3) stat mux —Select if you are using a Statistical

Multiplexer. This selection tends to be very

problematic, as stat muxes are not known for

reliability.

(4) auto —Do not select auto.

(5) none —Select if there is no PC running AM2000, or

if you do not wish for this NCC card to initiate calls to

the Network Manager.

(6) x.25 pad —Select if you are using an X.25 PAD.

Wait W)

Use this option to

determine how long the

NCC card will wait after an

alarm has occurred before

it attempts to report that

alarm to the management

PC.

interval 0-59S or 1-59M or 1-24H >

interval 0-59S or 1-59M or 1-24H >

interval 0-59S or 1-59M or 1-24H >

interval 0-59S or 1-59M or 1-24H >
Enter a numeric value in one of the ranges shown.

Include the letter “S” for that many seconds; “M” for

minutes or use “H” if you really want to wait for hours

before learning about alarm conditions.

Example—“15S” for fifteen seconds.

Use U1)

Use U2)

This screen selects

behavior for the Primary

(U1) and Secondary (U2)

communication paths

back to the management

PC.

If both primary and

secondary paths are

defined, the NCC will try

first one number and then

the other until a

management PC is

reached.

For each command, U1 or U2, the following prompt is

returned:

use (1) none (2) send (3) backup >

use (1) none (2) send (3) backup >

use (1) none (2) send (3) backup >

use (1) none (2) send (3) backup >
Select (1) to disable this function.

Select (2) to send according to the other options in

this menu.

Select (3) if this is your backup method of reporting

alarms.

Rate B1)

Rate B2)

B1 selects the baud rate

for the primary path to a

management PC.

B2 selects the baud rate

for the secondary path to

a management PC.

The following prompt appears:

rate (1) 1200 (2) 2400 (3) 4800 (4) 9600 >

rate (1) 1200 (2) 2400 (3) 4800 (4) 9600 >

rate (1) 1200 (2) 2400 (3) 4800 (4) 9600 >

rate (1) 1200 (2) 2400 (3) 4800 (4) 9600 >
Choose the highest rate in bits per second that your

communication path supports.

Attempt R1)

Attempt R2)

Selects the number of tries

(attempts to connect to

the network manager) for

the primary (R1) and

secondary (R2) paths to

the management PC(s).

The following prompt appears:

retry 0 to 254 or 255 for continuous >

retry 0 to 254 or 255 for continuous >

retry 0 to 254 or 255 for continuous >

retry 0 to 254 or 255 for continuous >
Enter a number for the attempts to be made.