Configuration, Using the craft interface, Craft port terminal setup – Verilink NCC 2020 (880-503284-001) Product Manual User Manual

Page 23: Using the craft interface -1, Craft port terminal setup -1, Chapter

Advertising
background image

Verilink NCC 2020 User Manual

3-1

Chapter

3

Configuration

This chapter covers using the Craft interface to configure the CSU
portion of the NCC 2020 Node Controller, and use of the front
panel thumbwheel switches.

Using the Craft Interface

To access the Craft interface, connect a terminal or a computer
running a terminal program to the port labeled C

RAFT

on the front

panel of the NCC 2020 module.

Craft Port

Terminal Setup

Set your terminal parameters to:

Data Rate : 19.2 kbit/s

Word Size : 8 bits

Parity : None

Stop Bits : One

Flow Control: None

The Verilink Craft interface does not assert any control leads.

NOTE: Although the Craft interface in the NCC 2020 will adjust

(autobaud) to your terminal rate, Verilink suggests using

19.2 kbit/s to conform to the requirements of other Verilink

products.

Verilink provides one of two types of "Craft cable". Both versions of
the Craft cable have an RJ-11 modular connector at one end. The
original cable has a female DB-25 connector at the otherend and a
more recent version has a DB-9 female connector. Connect the RJ-
11 modular connector to the port labeled

CRAFT

on the front of the

NCC 2020 module.

The original Craft cable pinout is as follows:

Table 3-1 Verilink Craft Cable p/n 458-501788-008

DB-25 female

RJ-11 modular

Usage

pin 2

pin 3

Transmit Data

pin 3

pin 4

Receive Data

pin 7

pin 5

Signal Ground