Port connections, Net (network), Dbu (dial backup) – Verilink PRISM 3002 (34-00277) Product Manual User Manual

Page 14: Port connections -2, Net (network) -2 dbu (dial backup) -2

Advertising
background image

2-2

I

NSTALLATION

Port
Connections

The front of the PRISM 3002 has one port connection: the Supervisory (SUPV),
discussed on page 2-3. The rear of the PRISM 3002 has three port connections:
DBU, NET, and Data Port as shown in Figure 2-1.

NET

(Network)

The network (NET) port provides connection to the network and contains an automatic
line build out (ALBO) allowing the unit to be located a substantial distance away from
the telco network interface with a receive signal level down to -27 dB.

The network interface LBO
level should be set as instructed
in section Line Parameters on
page 4 -15
. Maximum suggested
cable lengths for the connection
from the unit to the network are
listed in Table 2-1. Calculations
are based on a 70

°

F cable

temperature, a 0.083-

µ

F /mile

capacitance, a 27- dB line loss,
and a 100-

, non-loaded,

twisted pair cable.

The network physical interface is a standard
RJ-48C 8 -pin modular jack. Table 2-2
displays the pinout assignments.

In accordance with FCC Rules, Part
68.218(b), notify the telephone company before disconnecting this product.

DBU
(Dial

Backup)

The Dial Backup port provides an alternate path
when the T1 network interface service is disrupted
or performance quality is degraded. This port is a
10-pin RS-232 port that can connect, through a
connector adapter, to a public switched digital
network (PSDN) device such as a Verilink PS500.
Table 2-3 displays the pinout assignments. See Dial
Backup Parameters on page 4-20 for
more
information.

Table 2-1 Maximum Cable Lengths

Cable Type

Loss per
1000'

Max Cable
Length

26-gauge PIC

6.8 dB

4,400 ft

24-gauge PIC

5.4 dB

5,500 ft

22-gauge PIC

4.2 dB

7,100 ft

19-gauge PIC

3.0 dB

10,000 ft

PIC - Plastic Insulated Cable

Table 2-2 Network Interface Pinout

Pin

T1 NET Interface

1

Data In (Tip)

2

Data In (Ring)

3, 6

Not used

4

Data Out (Tip)

5

Data Out (Ring)

7, 8

Chassis Ground

Table 2-3 DBU Port Pinout

Pin

Connection

1

Rx Clock In

2

DTR Out

3

RTS Out

4

Frame Ground

5

Data Out

6

Data In

7

Signal Ground

8

CTS In

9

DCD In

10

Tx Clock In

Advertising