Portunloop, Fp buttons, Bert – Verilink PRISM 3002 (34-00277) Product Manual User Manual

Page 35: Pattern, Test length, Pattern sync, Elapsed time, Bit errors, Errored seconds, Port unloop -13 fp buttons -13

Advertising
background image

Maintenance Screen

4-13

causes the unit to transmit in-band V.54 fractional loop code toward the network in
the port’s bandwidth.

Port Unloop

Pressing Enter takes down the specified loop from the currently selected port.

FP Buttons

This field allows enabling or disabling the Test and Loop buttons on the unit front
panel.

BERT

This field selects the interface and direction for the test pattern transmission. The
choices are T1 NET, One NET, One DTE, Channel 1-24, and IDLE. The internal
BERT may also be activated through the front panel test switch as specified in
Controls and Indicators on page 3- 1.

Pattern

Specifies the pattern to be transmitted during a test. Modifying this field does not
cause the pattern to be transmitted (refer to on page 4- 14). The choices are QRSS,
63, 511, 2047, 2

15

, 2

20

, 2

23

, 1:8, 3:24, ALT, and Clear.

Test

Length

Defines the run- time of test pattern generation and error accumulation. The
choices are 15 min, 30 min, 60 min, 24 Hour, and Continuous.

Pattern

Sync

This field displays the current state of pattern sync during a test. If no test is in
progress, No Test is displayed. If a test is active, but the receiver is not in pattern
sync, No Sync is displayed. If the receiver is in pattern sync, In Sync is displayed.

Elapsed

Time

Displays the amount of time elapsed since a timed test began or, if completed, the
total test time.

Bit Errors

Displays the total number of bit errors detected since the test began or since error
statistics were cleared (up to 999,999).

Errored

Seconds

This field displays the number of asynchronous errored seconds that have been
detected since the test began or since error statistics were last cleared. This
parameter includes bit error seconds and sync loss seconds.

Network Interface

Framer/Deframer

multiplexer

Receivers /Drivers

Receivers/Drivers

BERT Generator /

Detector

EIA-530 or V.35

(100' max.)

Framer /Deframer

To

NET

From

NET

To Network

From Network

RJ48C

5

4

2

1

To

Ports

From

Ports

DTE

Near/Far

Port Loop (bidirectional)

Advertising