Dte alarms, Alarm status), Power loss seconds – Verilink PRISM 3002 (34-00277) Product Manual User Manual

Page 28: Reset alarm registers, Dte alarms -6

Advertising
background image

4-6

T

ERMINAL

C

ONFIGURATION

AND

T

ESTING

DTE Alarms

These status lines display the selected element’s current DTE signal alarm state
(Table 4-3). Alarms are determined by the selectable thresholds in the Alarm
Configuration screen (see Figure 4-8 on page 4-17).

Selectable thresholds in the Alarm Parameters screen and the DTR Alarm may be
enabled or disabled for the ports in the Port Parameters screen.

(alarm status)

The main body of the Alarms screen shows the current count for parameters that
may be used to trigger an alarm.

The Current column displays a total of the preceding 15 one -minute intervals. At
the end of each one-minute interval, the oldest minute of the 15 -minute interval is
discarded.

The Threshold column displays the values set in the Alarm Configuration screen
(see Figure 4-8 on page 4- 17). Parameters having a current value equal to or
greater than its non-zero threshold generates an alarm. Any parameter with a
threshold value of zero is disabled from generating alarms.

The parameters shown on the Alarms screen are updated at approximately five-second
intervals.

Power Loss Seconds

This field displays the number of seconds that the element has been without power
since this value was last cleared.

Reset Alarm Registers

Pressing Enter on (Reset) zeros the value of all Current alarm parameters, but does
not affect 24-hour or 30 -day performance registers.

Table 4-3 DTE Alarm Indicators

Alarm

Description

OK

No alarm threshold has been exceeded, although
errors may exist which do not exceed thresholds.

PORT 1

DTR Alarm on PORT 1.