Alarmsscreen, Net alarms, Alarms screen -5 – Verilink PRISM 3002 (34-00277) Product Manual User Manual

Page 27: Net alarms -5, Alarms screen

Advertising
background image

Alarms Screen

4-5

Alarms Screen

The Alarms screen (Figure 4-4) allows viewing the current alarm status of the
network and the DTE lines.

NET Alarms

These status lines display the selected element’s current network signal alarm state
(Table 4-2). Alarms are determined by the selectable thresholds in the Alarm
Configuration screen (see Figure 4-8 on page 4-17).

Figure 4-4 Alarms Screen

3002 DSU 1.00/2.40 3 0 0 2 Date: 06/24/97

No Far End Response Time: 08:36:09

------------------------------------ ALARMS ------------------------------------

Element: NEAR]

NET Alarms: NONE

DTE Alarms: NONE

Current Threshold

Loss of Signal Seconds (LOSS): 0 5

Errored Seconds (ES): 0 45

Severely Errored Seconds (SES): 0 5

Unavailable Seconds (UAS): 0 0

Out of Frame Seconds (OOFS): 0 5

Remote Alarm Seconds (RAS): 0 0

AIS Seconds (AISS): 0 0

BPV Seconds (BPVS): 0 0

Power Loss Seconds (PLS): 0

Reset Alarm Registers: (RESET)

----------------------------------- Messages -----------------------------------

Local Screen

Table 4-2 NET Alarm Indicators

Alarm

Description

-------

No status is available.

OK

No alarm threshold has been exceeded, although errors
may exist which do not exceed thresholds.

ERRS

The Errored Seconds, Severely Errored Seconds, or
Bipolar Errored Seconds threshold is exceeded.

LOSS

The Loss Of Signal Seconds threshold is exceeded.

OOFS

The Out Of Frame Seconds threshold is exceeded.

RAIS

The Remote Alarm Seconds threshold is exceeded.

AISS

The Alarm Indication Seconds threshold is exceeded.

UAS

The Unavailable Seconds threshold is exceeded.

DBA

Dial Backup Active.

DBF

Dial Backup Failed.

Advertising