Out of Frame Seconds

A one-second period in which a frame sync loss occurred.

BPV Seconds

A one-second period in which at least one bipolar violation occurred.

Alarm Reset Timer

Determines the number of seconds after alarm conditions clear before indications
are removed.

Port

Configuration

The Port Configuration screen (Figure 4-9) sets the operating parameters for the
high-speed port. The default is all channels enabled.

When channel assignment changes are made to the high- speed port or to the
remote communication link, the 3002 reestablishes the mapping of all channels.
This interruption to traffic normally results in a brief burst of data errors.

Channel Allocation

This display-only field indicates the network channel assignments with Channel 1
on the left and Channel 24 on the right. Channels assigned to a port are identified
with a port number (always 1). Non-assigned idle channels are marked with a
hyphen (-). Remote communication channels are marked with an R. When
channels are assigned to a port in the Alternate assignment mode, each data
channel is followed by an idle channel not assignable for other ports and is marked
with an X.

Port #

Selects the port to be configured. This value is always One.

Figure 4-9 Port Configuration Screen

3002 DSU 1.00/2.40 3 0 0 2 Date: 06/24/97

No Far End Response Time: 08:42:36

--------------------------- PRISM Port Configuration ---------------------------

Element: [NEAR]

Channel Allocation: ------ ------ ------ ------

Port # [ONE ]

LL Detect : [DISABLE]

Rate Mult: [N x 64k] RL Detect : [DISABLE]

DS0 Ch. Assign: [Contiguous] V.54 Loop : [ENABLE ]

Invert Data: [No ]

Start Ch. #: ( 0) CTS Control: [Force True ]

Port Rate: [0 kHz ] DSR Control: [Force True ]

# of Channels: 0 DCD Control: [Force True ]

Tx Clock: [Internal ] Alarm on DTR Loss: [DISABLE]