Far llb, Dte mlb, Far llb – Verilink PRISM 3002 (34-00277) Product Manual User Manual

Page 34: Portloop, Far llb -12 dte mlb -12 far llb -12 port loop -12

Advertising
background image

4-12

T

ERMINAL

C

ONFIGURATION

AND

T

ESTING

FAR LLB

A NET LLB can be activated on the far-end unit through this selection or through
the front panel TEST button.

DTE MLB

The DTE MLB command loops all network data back toward the DTE ports at the
network interface. Data is passed through to the network. Set the T1-NET Timing
to Internal when this loop is enabled.

Far LLB

This field appears when the T1 Loop is set to Far LLB. Valid options for this field
are Framed and Unframed. This setting must match the far-end unit loop code
framing.

Port Loop

This field is used to loop a high-speed data port from the network back to the
network and data from the DTE back to the DTE. The Port Loop may be activated
by receiving in-band V.54 fractional loop code or by this field. The Port Loop only
has ports with channels allocated to them as selections. Ports without channels
allocated appear as blank fields

A Port Loop is activated on the remote-end unit through this field or by the front
panel test switch. The test switch can be used to activate a remote Port 1. This

Network Interface

Framer /Deframer

multiplexer

Receivers /Drivers

BERT Generator /

Detector

EIA-530 or V.35

(100' max.)

From

NET

To

NET

To Network

From Network

RJ48C

5

4

2

1

To

Ports

From

Ports

NET

LLB

Receivers /Drivers

Framer /Deframer

Network LLB

Network Interface

Framer /Deframer

multiplexer

Receivers /Drivers

Receivers/Drivers

BERT Generator /

Detector

EIA-530 or V.35

(100' max.)

Framer /Deframer

From

NET

To

NET

To Network

From Network

RJ48C

5

4

2

1

To

Ports

From

Ports

DTE

MLB

DTE MLB