Power connection, Power failure, Power connection -4 power failure -4 – Verilink PRISM 3002 (34-00277) Product Manual User Manual

Page 16: Figure 2-2

Advertising
background image

2-4

I

NSTALLATION

The SUPV port bit rates are configured through Switch S1 (see SUPV Port Bit
Rate on page 3-2)
and programmed through the Management Ports menu on page
4-22.
This port is a DCE port configured for 8 bits, no parity, and 1 stop bit. The
physical connections are 8 -pin modular jacks (electrically RS-232). Figure 2-2
provides the pinout assignments. Refer to Table 1-2 on page 1 -5 for cable
information.

Power

Connection

Power to the 3002 is supplied
through the card-edge connection
when the unit is installed in the
1024 chassis. The 3002 requires a
-48 VDC power source capable
of supplying a 150 -mA current
from the chassis. All units in the
chassis are powered by -48 VDC
sources which are connected to
the 6 -position terminal strip,
TB1, on the rear of the 1024
chassis as shown in Figure 2-3.

Power

Failure

The PRISM 3002 provides non -volatile memory retention of the unit configuration
in case of a power failure. This feature allows the unit to automatically restore
normal service following a power loss. When power is applied to the unit, the front
panel indicators flash for approximately five seconds as the unit starts up.

Figure 2-2 SUPV Terminal/Modem Connections

DTR Out

1

RTS Out

2

Frame Gnd

3

Data Out

4

Data In

5

Signal Gnd 6
CTS

In 7

DCD

In 8

PC (DTE)

SUPV Port

1 DCD
8

CTS

5

Frame Gnd

2

RXD

3

TXD

NC Signal Gnd
7

RTS

4

DTR

8-Pin

DB-9

Modular

DTR Out

1

RTS Out

2

Frame Gnd

3

Data Out

4

Data In

5

Signal Gnd

6

CTS

In 7

DCD

In 8

Modem (DCE)

SUPV Port

20 DTR
4

RTS

1

Frame Gnd

2

TXD

3

RXD

7

Signal Gnd

5

CTS

8

DCD

8-Pin

DB-25

Modular

Verilink
1024
Chassis

Verilink
1042
Power
Supply

+

GND

1 +48VDC IN A

2

3 -48VDC IN A

TB1

4 -48VDC IN B

5

6 +48VDC IN B

Figure 2-3 Wiring for a Single Power Source

PS A

PS B

+

GND

Advertising