Front Panel Port Connections



7

Front Panel Port
Connections

The PRISM 3301 contains a local access port and two BNC access jacks on the
front panel for monitoring and user interaction.

Local Access

The local access port (located on the front panel) requires an RS-232, DB-9 male
connector to connect to an ASCII terminal or computer running a terminal
emulation software package at speeds of 1200, 2400, 4800, 9600, or 19,200 bps.
This port can be configured as dial-in/dial-out. The PRISM 3301 automatically
answers any incoming calls. If a value is entered into the Dial String field, it
attempts to place a call to the designated number. Once a connection is established,
the unit sends an ASCII alarm string containing the date, time, alarm description,
and application identification. If a connection is not established, the COA routine
continues for up to six attempts.

Monitor

The two BNC access jacks labeled Tx and Rx on the front panel allow for
non-intrusive monitoring of the network signal.

Rear Panel Port
Connections

The PRISM 3301 contains an AC-power receptacle, a grounding stud, a T3
network interface with backup unit connectors, a high-speed serial interface (HSSI)
DTE interface, and an RS-232 network management port with embedded SNMP.

Network

The T3 network interface connects the PRISM 3301 to a T3 network. The backup
unit connectors allow the DS3 line to be switched to a backup unit in the event of
power outage, watchdog failure, or CPU self-test failure.

The primary connections require cables with 75

BNC connectors to the T3

facility. The secondary connections require cables with 75

BNC connectors to the

hot-standby unit.

DTE

The High-speed Serial Interface (HSSI) port transmits data to and receives data
from DTE equipment at data rates of 3.16, 6.32, 12.63, 18.95, 25.26, 31.58, 37.70,
and 44.21 Mbps. The DTE port requires a cable with an Amplimite 50-pin male
connector. The pinout for the HSSI DTE interface is provided in Table 2-1.

O
N

1

2

3

4

USE ONLY WITH 250V FUSE

NETWORK

IN

OUT

IN

OUT

PRIMARY

SECONDARY

PRIMARY

DTE

NETWORK

MGMT

(RS232)

CONTROL

SWITCH

ON

OFF

CAUTION:

TO PREVENT RISK OF

FIRE USE SAME TYPE\

RATING OF FUSE

110V, .5A

50/60HZ

GND

250V, 2A

Primary Power

Receptable

4-Pin

DIP Switch

RS-232

Serial Comm.

Interface with

Embedded SNMP

High-Speed

Serial Interface

(HSSI)

DTE Interface

To

Hot-Standby

Unit

T3 Network Interface

IN

IN

OUT

OUT

Figure 2-3 PRISM 3301 Rear Panel