AC Power
The PRISM 3301 requires a 110 -volt AC power supply. The rear panel power
receptacle is an industry standard male recessed receptacle with grounding pin.
The grounding pin is a safety feature. Do not defeat the purpose of the grounding
plug. If the plug does not fit into the outlet, contact the facility manager or a
qualified electrician to replace the outlet with a properly-grounded outlet. The
power block contains a 2 amp, slow blow 250 V fuse.
To avoid an electrical shock hazard, remove power connections to the PRISM 3301
during installation. If the fuse opens, replace it with a 250 V, 2 amp, slow blow fuse.
To connect the 110 VAC power cord:
1
Firmly connect the socket end of the supplied power cable to the recessed power
receptacle located at the rear of the unit.
2
Plug the other end of the power cord into the three-hole, grounded AC outlet.
Ground Stud
A ground stud located on the rear panel allows for a chassis ground when
necessary.