35

t3DatalinkConfig

{ 1.3.6.1.4.1.425.2.8.1.2 } This table defines the PRISM 3301 Datalink
Configuration, Status, and Control Objects.

t3DteConfig

{ 1.3.6.1.4.1.425.2.8.1.3 } This table defines the PRISM 3301 DTE Configuration,
Status, and Control Objects.

Object Name

Object ID

User Access Object Description

t3DatalinkIndex

t3DatalinkConfigEntry 1

read-write

The value for this object is equal to the value of IfIndex from the
Interfaces table of MIB II (RFC 1213).

t3DatalinkEIC

t3DatalinkConfigEntry 2

read-write

A string containing the Equipment Identification Code (10 characters
maximum).

t3DatalinkLIC

t3DatalinkConfigEntry 3

read-write

A string containing the Location Identification Code (11 chrs max).

t3DatalinkFIC

t3DatalinkConfigEntry 4

read-write

A string containing the Frame Identification Code (10 chrs max).

t3DatalinkUIC

t3DatalinkConfigEntry 5

read-write

A string containing the Unit Identification Code (6 chrs max).

t3DatalinkPID

t3DatalinkConfigEntry 6

read-write

A string containing the Path Identification (38 chrs max).

t3DatalinkISID

t3DatalinkConfigEntry 7

read-write

A string containing the Idle Signal Identification (38 chrs max).

t3DatalinkTSID

t3DatalinkConfigEntry 8

read-write

A string containing the Test Signal Identification (38 chrs max).

t3FarEndISID

t3DatalinkConfigEntry 9

read-only

A string containing the Far End Idle Signal Identification.

t3FarEndTSID

t3DatalinkConfigEntry 10 read-only

A string containing the Far End Test Signal Identification.

t3Terminal

t3DatalinkConfigEntry 11 read-write

The type of terminal.
1 - DTE
2 - Carrier

Object Name

Object ID

User Access Object Description

t3DteIndex

t3DteConfigEntry 1

read-only

The value for this object is equal to the value of IfIndex from the Interfaces
table of MIB II (RFC 1213).

t3DteRate

t3DteConfigEntry 2

read-write

HSSI data rate. Only r3158 and r6316 should be written.
1 - r3158 (3.158 MHz)
2 - r6316 (6.316 MHz)
3 - r12631 (12.631 MHz)
4 - r18947 (18.947 MHz)
5 - r25263 (25.263 MHz)
6 - r31578 (31.578 MHz)
7 - r37894 (37.894 MHz)
8 - r44210 (44.210 MHz)

t3DteCA

t3DteConfigEntry 3

read-write

This object is bit mapped. When the bit is set it is On, and Off when the bit
is clear.
1 - Turn CA On/Off during LOS
2 - Turn CA On/Off during OOF
4 - Turn CA On/Off during RXAIS
8 - Turn CA On/Off during RXYELLOW
This object can represent multiple setting simultaneously.

t3DteLoopback

t3DteConfigEntry 4

read-write

This variable represents the loopback configuration of the PRISM 3301's
DTE interface.
1 - t3DteNoLoop - Not in the loopback state
2 - t3LocalDteLoop - DTE port is currently looped at the DTE interface
3 - t3LocalLineLoop - The DTE port is currently looped at the T3 interface

t3DteStatus

t3DteConfigEntry 5

read-write

This object is bit mapped. When the bit is set, it is On and Off when the bit
is clear. The various bit positions are as follows.
1 - On if NO DTE alarms active
2 - On during DTE CLOCK LOSS
4 - On during other DTE alarm
8 - On if any DTE loopback is active
This object can represent multiple settings simultaneously.