RFC 1407 MIB



31

dsx3SendCode

dsx3ConfigEntry 7

read-write This variable indicates what type

of code is being sent across the
DS3/E3 interface by the device.
(These are optional for E3
interfaces.)

dsx3SendNoCode(1) - the unit is
not in a BERT Test and not sending
a PLB or LLB loopup/loopdown
request to the far end.
dsx3SendLineCode(2) - the unit is
transmitting an in-band LLB loopup
signal. Since this occurs so quickly,
this response probably will not be
seen.

dsx3CircuitIdentifier

dsx3ConfigEntry 8

read-write This variable contains the

transmission vendor's circuit
identifier, for the purpose of
facilitating troubleshooting.

Returns the value of the Circuit
Identifier for the unit, this is
selectable in the Element.
Configuration Screen.

dsx3LoopbackConfig

dsx3ConfigEntry 9

read-write This variable represents the

loopback configuration of the
DS3/E3 interface.

dsx3NoLoop(1) - the unit does not
have any loops active.
dsx3LineLoop(3) - the received
signal at this interface does not go
through the device (minimum
penetration) but is looped back out.

dx3LineStatus

dsx3ConfigEntry 10 read-only

This variable indicates the Line
Status of the interface. It contains
loopback state information and
failure state information. The
dsx3LineStatus is a bit map
represented as a sum, therefore, it
can represent multiple failures and
a loopback simultaneously (see
dsx3LoopbackConfig object for
the type of loopback). The
dsx3NoAlarm should be set if and
only if no other flag is set.

(1) dsx3NoAlarm - No alarm
present

(2) dsx3RcvRAIFailure -
Receiving Yellow/Remote Alarm
Indication

(4) dsx3XmitRAIAlarm -
Transmitting Yellow/Remote Alarm
Indication

(8) dsx3RcvAIS - Receiving AIS
failure state

(16) dsx3XmitAIS - Transmitting
AIS

(32) dsx3LOF - Receiving LOF
failure state

(64) dsx3LOS - Receiving LOS
failure state

(128) dsx3LoopbackState -
Looping the received signal

(256) dsx3RcvTestCode -
Receiving a Test Pattern

(512) dsx3OtherFailure - Any line
status not defined here

dsx3TransmitClockSource dsx3ConfigEntry 11 read-write The source of Transmit Clock is

derived from the recovered receive
clock of another DS3 interface.

loopTiming(1) - the Network
Timing is set to Network Clock.

Object Name

Object ID

User
Access

Object Description

Get / Set

Advertising