RX AIS
13
Table 3-1 DTE and Network Alarm Conditions and Responses
Alarm Type
LED Signal(s)
Description
Operator Response
Loss of DTE Clock
TxAIS
DTE CLK LOSS
Send AIS Alarm on the
Network Output Signal
Log alarm in the alarm queue (including printing
the message on the ASCII terminal).
Loss of Input
Tx YELLOW
Network LOS
Yellow Alarm on the
Network Output Signal
Send all 1s to the DTE port.
Turn off CA signal of the DTE port if configured.
Log alarm in the alarm queue.
DS3 Frame Loss
Tx YELLOW
Network OOF
Yellow Alarm on the
Network Output Signal
Send all 1s to the DTE port.
Turn off CA signal of the DTE port if configured.
Log alarm in the alarm queue.
AIS
Network Rx AIS
Send all 1s to the DTE port.
Turn off CA signal of the DTE port if configured.
Log event in the alarm queue.
Yellow Alarm
Network Rx Yellow
Turn off CA signal of the DTE port configured.
Log the event in the alarm queue.
BPV
BPV
Log the event in the alarm queue.
Parity Error
Parity Error
Log the event in the alarm queue.
Remote Parity Error
Remote Parity Error
Log the event in the alarm queue.