Westermo TDW-33 User Manual

Page 12

Advertising
background image

6618-3202

12

%En – Enable/Disable Line Quality Monitor and Auto-Retrain or

Fallback/Fall Forward

Supported by:

TDW-33

TD-36

TD-36 485

TR-36

TR-36B

Description:

Enable/disable Line quality Monitor and Auto-Retrain or Fall back/fall forward.
This command controls if the modem automatically monitors the line quality and
requests a retrain (%E1) or fall back when line quality is insufficient or a fall forward
when line quality is sufficient (%E2). Set S41 bits 2 and 6.

Syntax:

AT%E<n>

Parameters:

<n>

0:

Disable Line Quality and auto-retrain

1:

Enable Line Quality and auto-retrain

2:

Enable Line Quality Monitor and Fallback/Fall Forward / (Default)

Command example

Possible responses

Note

AT%E<n> OK

The command is valid
and accepted

ERROR

Otherwise

S register: The value is written to S41 bits 2 and 6.