Westermo TDW-33 User Manual

Page 60

Advertising
background image

6618-3202

60

Zn – Soft Reset

Supported by:

TDW-33

TD-36

TD-36 485

TR-36

TR-36B

Description:

This command do a soft reset and restores the configuration profile according to the
parameter supplied.
If no parameter is specified, zero is assumed.

Syntax:

ATZ<n>

Parameters:

<n>

0: Soft reset, profile 0
1: Soft reset, profile 1

Command example

Possible responses

Note

ATZ<n>

OK

<n> = 0,1

ERROR

Otherwise

S register: None.

&Zn = x – Store Telephone Number

Supported by:

TDW-33

TD-36

TD-36 485

TR-36B

Description:

The modem can store up to four telephone numbers and each telephone number
dial string can contain up to 31 digits. Entry 0 is used for DTR and TxHotline call, see
AT&B<n>

Syntax:

AT&Z<n> = <string>

Parameters:

<n>

0:

Telephone number 0

1: Telephone number 1
2: Telephone number 2
3: Telephone number 3

<string>
Dial string from 0 to 31 characters

Command example

Possible responses

Note

AT&Z<n> = <string>

OK

The number is stored

ERROR

Otherwise

S register: None.