Westermo TDW-33 User Manual

Page 73

Advertising
background image

6618-3202

73

Register

Function

Range

Units

Saved

Default

Note

S210

General func-
tion bitmap

0-255

-

*

5

Bit 0: Break control
0 = Inactive, 1 = Active

Bit 1: Protocol
0 = Inactive, 1 = Active

Bit 2: Remote config
0 = Inactive, 1 = Active

Bit 3: Ignore error
0 = Inactive, 1 = Active

Bit 4: DTR hot-call
0 = Inactive, 1 = Active

Bit 5: TX hot-call
0 = Inactive, 1 = Active

Bit 6: TX hot-call buffers: 0
= Send buffer data,
1 = Empty buffer

Bit 7: Remote upgrade:
0 = Inactive,
1 = Active

S211

On-hook
timer delay

0-255

ms

*

0

0 = No delay

S212

Off-hook
timer delay

0-255

ms

*

0

0 = No delay

S213

DCE data
out timer
delay

0-255

ms

*

0

0 = No delay

S214

General
function
bitmap

-

-

-

6

Bit 0: No Line speed limit
(DTEvsLINE): 0 = Inactive,
1 = Active (Default = 0)

Bit 1: V.23 HDX PSTN inac-
tivity timer: 0 = Inactive,
1 = Active (Default = 1)

Bit 2: V.23 HDX/FDX no
disconnect on DCD drop:
0 = Inactive, 1 = Active
(Default = 1)

Bit 3: V.23 HDX activity
timer: 0 = Inactive,
1 = Active (Default = 0)

Bit 4: V.23 HDX activ-
ity timer no recovery: 0 =
Inactive, 1 = Active
(Default = 0)

Bit 5: Reserved

Bit 6: Reserved

Bit 7: Reserved

Advertising
This manual is related to the following products: